• MCB L7 Mini Circuit Breaker
  • MCB L7 Mini Circuit Breaker
  • MCB L7 Mini Circuit Breaker
  • MCB L7 Mini Circuit Breaker
  • MCB L7 Mini Circuit Breaker
  • MCB L7 Mini Circuit Breaker

MCB L7 Mini Circuit Breaker

Breaking Capacity: Low Voltage Circuit Breakers
Operation: Manual Type
Speed: Normal Type Circuit Breaker
Arc-extinguishing Medium: Oil-immersed Type
Installation: Fixed
Structure: MCB
Customization:
Gold Member Since 2008

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
L7
Type
Circuit Breaker
Function
Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection)
Certification
CE, CCC
Origin
Zhejiang China (Mainland)

Product Description

The products of L7 belong to the advanced level of the nineties in the world instead of the older generation of kl7. They have protective function as shortage as overload, and are used in lighting distribution system in industry, commerce and dwelling, and protect fractional electric motors. And they also have many merits of high protective grade (up to IP20), high break capacity, reliable sensitive action, convenient, multiple assembling, long life etc. They are mainly adapted to the circuit of AC 50Hz, 230V in single pole, 400V in double, three, four poles for protecting overload and short circuit. Meanwhile, they are also used in turning on or off the electric apparatus and lighting circuit under the normal condition.

Specification Electrical Specification
Conforms To Standard Of Electrical: En60898(Iec898) GB10963-99
Rated Current(Ue): 230V/440V; 50/60Hz
Rated Breaking Capacity: 10ka Iec898(0.5~63A)
15ka Iec947-2(0.5~63A)
Short Circuit Breaking Capacity Of DC: Max. 48V(Kl7...., 10ka)Single Pole
Max. 250V(Kl7-DC, 6ka)Single Pole
Perfermance: C, D Charactisistic Curve
Max. Fuse That Can Be Connected To: 100agl(10ka)
Selective Grade: 3
Working Ambient Temperature: -5 To+40
Enclosed Protective Class: P40(Under Mounting)
Life: Electrical Mechanical Not Less Of 8000times Switching Operation
Not Less Of 20000 Times Switching Operation

Mechanical Specification
The Length Of Exposed Plane: 45mm
Enclosure Height: 80mm
Enclosure Width: 17.5mm Per Pole(Single Pole)
35mm: 1p+N(Two Poles)
Mounting Manner: Used For Track Of 35mm Of Iec Standard
Terminal Manner: Two-Function Terminal Can Connect With Busbar And Conducting Wire
Terminal Block Capacity: Wire 1-25mm2
Conducting Wire 0.8-2mmMCB L7 Mini Circuit Breaker

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now